Steam trap types compared
A steam trap lets condensate and air out while holding steam in. Each type suits a different duty.
| Type | How it works | Best for | Page |
|---|---|---|---|
| Thermodynamic (TD) | A disc opens and closes on the difference between steam and condensate flow | Steam mains drainage, tracing, small loads | TD Trap |
| Float and thermostatic | A float lifts to discharge condensate continuously; a thermostatic element vents air | Heat exchangers, process plant with changing loads | Steam Trap |
| Venturi (fixed orifice) | A sized nozzle with no moving parts | Steady loads where sizing is known | Venturi Traps |
| Pump trap (MFP) | Uses steam or air pressure to push condensate out | Where back pressure stops a normal trap draining | MFP Unit |
| Air vent | A thermostatic element releases air and gases | High points and the ends of steam mains | Air Vent |
Boiler safety devices compared
| Device | What it protects against | Page |
|---|---|---|
| Safety / relief valve | Pressure rising above the set limit | Relief Valves |
| Pressure switch | Burner running above the working pressure; switches it off | Pressure Switch |
| Fusible plug | Low water level overheating the furnace | Fusible Plug |
| Boiler hooter | Alarm conditions going unnoticed | Boiler Hooter |
| Gauge glass (reflex) | Not seeing the true water level | Reflex Glasses |
| Blowdown valve | Sludge and dissolved solids building up | Blowdown Valve |
Safety valves and pressure switches should be set and tested by a competent person in line with the boiler maker instructions and inspection requirements.
Steam separator sizes
Steam separators remove water droplets from steam before it reaches control valves and equipment. Every size page links to the others. Fit a steam trap on the separator drain.
Single vs double AKO controller
| Single | Double | |
|---|---|---|
| Controls | One temperature or output | Two temperatures or outputs |
| Typical use | One heater, one cooling stage or one alarm | Two stages, or heating and cooling from one unit |
| Page | Single controller | Double controller |
Pair these with steam valves, spiral gaskets, pressure gauges and burner spares.
Frequently asked questions
Which steam trap should I use?
Why do I need a steam separator?
What does a fusible plug do?
How often should boiler gauge glasses be replaced?
What is boiler blowdown?
How do I order boiler accessories?
Need boiler accessories? Send the type, size and quantity on WhatsApp 0726 086 895 or email sparksplumbingexperts@gmail.com, and we will confirm what is available from Enterprise Road, Industrial Area, Nairobi.