Buy AC and refrigeration tools in Kenya: refrigerant gases, copper pipe coils, manifold gauges, flaring kits, pipe cutters, brazing torches, recovery units, leak detectors, condensate pumps, AC brackets and cold room hardware, grouped by type. Compare tools and refrigerants below.
Shop by size, capacity and gas
Shop by type
Installation and service tools
Leak finding and repair
Condensate pumps
Cold room hardware
Showing 1–24 of 76 results
Which tool for which job
A clean, dry, leak-free system starts with the right tools. This table matches each tool to the step of the job.
| Job | Tools and parts | Why it matters |
|---|---|---|
| Cutting and preparing pipe | Pipe cutter, deburrer, copper pipe | A square, clean cut gives a sound flare or braze joint |
| Flare joints | Flaring kit | A correct flare seals without leaks at the unit connections |
| Brazed joints | Brazing torch, brazing gas, MAPP torch | Strong joints on larger pipes and copper fittings |
| Reading pressures | Low side gauge, high side gauge, charging hose | Charging and fault finding depend on accurate readings |
| Charging | Charging valves, refrigerant | The correct gas and charge keep the compressor safe |
| Recovering gas | Recovery unit, recovery cylinder | Refrigerant is recovered instead of vented |
| Finding leaks | Leak detector | Fixing the leak first stops repeat call-outs |
| Draining condensate | M1 condensate pump, PC-24B pump | Removes water where a gravity drain is not possible |
| Mounting outdoor units | AC brackets, wall brackets | A level, secure unit runs quieter and lasts longer |
Refrigerants compared
Every refrigerant page links to the others. Never mix gases in one system.
| Refrigerant | Type | Typical use | Notes | Page |
|---|---|---|---|---|
| R22 | HCFC | Older split ACs, cold rooms | Being phased out; for servicing existing systems | View |
| R32 | HFC | Newer split ACs | Mildly flammable (A2L) | View |
| R134a | HFC | Car AC, fridges, medium temperature | Common in automotive and commercial refrigeration | View |
| R404A | HFC blend | Freezers, low temperature cold rooms | Charge as liquid | View |
| R407C | HFC blend | Air conditioning, some R22 replacements | Charge as liquid; check oil compatibility | View |
| R410A | HFC blend | Split and ducted ACs | Higher pressure; needs rated gauges and hoses | View |
| R290 | Hydrocarbon | Small commercial and display units | Flammable (A3); trained handling only | View |
| R600a | Hydrocarbon | Domestic fridges and freezers | Flammable (A3); trained handling only | View |
Read more: refrigerant gases explained.
Low side vs high side gauge
| Low side (blue) | High side (red) | |
|---|---|---|
| Reads | Suction pressure | Discharge or liquid pressure |
| Connects to | Suction (gas) service port | Discharge or liquid service port |
| Used for | Charging vapour, checking evaporating pressure | Checking condensing pressure and system faults |
| Page | Low side gauge | High side gauge |
Check that gauges and hoses are rated for the refrigerant pressure, especially for R410A and R32.
Leak detector vs stop leak
| Leak detector | Stop leak sealant | |
|---|---|---|
| What it does | Finds the leak so it can be repaired | Seals very small leaks from inside the system |
| Best for | Every service call with a low charge | Tiny leaks that cannot be reached, as a last resort |
| Watch out for | Calibrate and keep sensors clean | Follow the maker instructions; some service equipment must be protected from sealants |
Frequently asked questions
What tools do I need to install a split AC?
Can I use R22 gauges on an R410A system?
Why should refrigerant be recovered?
Which refrigerant does my AC use?
When do I need a condensate pump?
How do I order tools?
Need AC and refrigeration tools? Send the type, size and quantity on WhatsApp 0726 086 895 or email sparksplumbingexperts@gmail.com, and we will confirm what is available from Enterprise Road, Industrial Area, Nairobi.