Buy copper pipe coils in Kenya: soft annealed copper tube in 15 m rolls for split AC line sets, fridges, cold rooms and gauge lines. Sizes run from 1/8 to 2 1/8 inch OD. Pick a size below, or compare coils with straight copper pipe.
Shop by size
Showing all 18 results
Coil or straight?
Coils bend on site and cut down on joints. Straight lengths suit plant rooms and headers. See the full coil vs straight comparison.
| Copper pipe coil | Straight copper pipe | |
|---|---|---|
| Form | Tube wound into a 15 m coil | Rigid straight lengths |
| Temper | Soft annealed | Hard-drawn |
| Bending | Bends by hand or with a tube bender | Stays straight; direction changes use elbows or bends |
| Typical joints | Flare nuts at units, brazing on long runs | Brazing with copper fittings |
| Joints per run | Fewer, because one length follows walls and corners | More, because each change of direction needs a fitting |
| Best for | Split AC line sets, refrigeration repairs, gauge lines | Plant rooms, headers, risers and neat exposed runs |
| Handling | Compact and easy to carry to site | Needs a vehicle and safe storage to stay straight and clean |
| Sizes listed | 1/8 inch to 2 1/8 inch | 3/8 inch to 2 1/8 inch |
Copper pipe size chart
| Size (OD) | mm | Coil (15 m) | Straight | Commonly used for |
|---|---|---|---|---|
| 1/8 inch | 3.18 | View coil | Not listed | Gauge and pressure switch connections, short instrument lines |
| 1/4 inch | 6.35 | View coil | Not listed | Liquid line on small wall split ACs; fridges, freezers and display chillers |
| 3/8 inch | 9.52 | View coil | View straight | Liquid lines on mid-size split and ducted ACs; suction on small refrigeration units |
| 1/2 inch | 12.7 | View coil | View straight | Suction (gas) line on small wall split ACs; liquid lines on larger systems |
| 5/8 inch | 15.88 | View coil | View straight | Suction lines on mid-size split and ducted ACs and small cold rooms |
| 3/4 inch | 19.05 | View coil | View straight | Suction lines on larger split, ducted and packaged AC units |
| 7/8 inch | 22.23 | View coil | View straight | Suction lines on larger ducted and packaged units and cold room condensing units |
| 1 1/8 inch | 28.58 | View coil | View straight | Suction and discharge lines on packaged units, cold rooms and small chiller plant |
| 1 1/4 inch | 31.75 | View coil | Not listed | Larger lines where this size is already installed; check the match on site |
| 1 3/8 inch | 34.93 | Not listed | View straight | Suction headers on cold rooms, multi-compressor racks and chiller plant |
| 1 5/8 inch | 41.28 | View coil | View straight | Large suction headers and risers on commercial refrigeration and chiller plant |
| 2 1/8 inch | 53.98 | View coil | View straight | Main suction headers on large refrigeration racks, chillers and industrial cooling plant |
Wall thickness and length per straight piece depend on the batch, so confirm both with your quote, especially for R410A and R32 systems.
Tips for working with copper coils
- Unroll the coil on a flat surface instead of pulling the end, to avoid kinks.
- Keep the ends capped until you connect them, so dust and moisture stay out.
- Use a tube bender for tight bends to keep the bore round.
- Cut with a tube cutter and deburr before flaring.
- Pressure test and evacuate the system before charging with refrigerant.
Frequently asked questions
What is the difference between a copper pipe coil and a straight copper pipe?
A coil is soft annealed copper wound into a 15 m roll that bends by hand or with a bender. A straight pipe is hard-drawn copper supplied in rigid lengths that stay straight and are joined with brazed fittings.
Are copper pipe sizes measured on the inside or the outside?
Refrigeration copper tube is named by its outside diameter (OD). A 1/2 inch tube has an outside diameter of 12.7 mm.
Which copper pipe sizes does a split AC need?
Small wall split units commonly use 1/4 inch for the liquid line and 3/8 or 1/2 inch for the suction line. Always follow the sizes printed in the indoor or outdoor unit manual.
Is a copper pipe roll the same as a copper pipe coil?
Yes. Roll and coil are two names for the same soft copper tube wound into a coil.
Can I use these copper pipes for R410A and R32?
Confirm the wall thickness with your quote before you order. R410A and R32 run at higher pressures than R22, so the tube wall must suit the system pressure.
Do I need to insulate copper refrigerant pipes?
Yes, the suction line in particular. Insulation stops condensation and heat gain. Match the Armaflex tube size to the copper OD; see our insulation range.
What tools do I need to install copper pipe?
A tube cutter, deburrer, flaring tool, tube bender for coils, and brazing equipment for straight lengths. Browse our refrigeration and AC tools.
How do I order copper pipe from Sparks Plumbing Experts?
Send the sizes, coil or straight form and quantity on WhatsApp 0726 086 895 or email sparksplumbingexperts@gmail.com. We supply from Enterprise Road, Industrial Area, Nairobi.
Need copper pipe for a job? Send the sizes, coil or straight, and the quantity on WhatsApp 0726 086 895 and we will confirm what is available.