Find copper pipes in Kenya for air conditioning and refrigeration, grouped by size and form. Choose soft copper pipe coils of 15 m from 1/8 to 2 1/8 inch, or hard-drawn straight copper pipe from 3/8 to 2 1/8 inch, then compare the two forms below and request a quote.

Shop by size

Showing 1–24 of 28 results

Copper pipe coil vs straight copper pipe

Both forms are copper tube named by outside diameter. The difference is temper and shape: coils are soft and bend on site, straight lengths are hard and stay rigid. Use the table to decide which suits your job.

Copper pipe coilStraight copper pipe
FormTube wound into a 15 m coilRigid straight lengths
TemperSoft annealedHard-drawn
BendingBends by hand or with a tube benderStays straight; direction changes use elbows or bends
Typical jointsFlare nuts at units, brazing on long runsBrazing with copper fittings
Joints per runFewer, because one length follows walls and cornersMore, because each change of direction needs a fitting
Best forSplit AC line sets, refrigeration repairs, gauge linesPlant rooms, headers, risers and neat exposed runs
HandlingCompact and easy to carry to siteNeeds a vehicle and safe storage to stay straight and clean
Sizes listed1/8 inch to 2 1/8 inch3/8 inch to 2 1/8 inch

Copper pipe size chart

Every size we list, with its metric outside diameter and whether it comes as a coil, a straight length or both.

Size (OD)mmCoil (15 m)StraightCommonly used for
1/8 inch3.18View coilNot listedGauge and pressure switch connections, short instrument lines
1/4 inch6.35View coilNot listedLiquid line on small wall split ACs; fridges, freezers and display chillers
3/8 inch9.52View coilView straightLiquid lines on mid-size split and ducted ACs; suction on small refrigeration units
1/2 inch12.7View coilView straightSuction (gas) line on small wall split ACs; liquid lines on larger systems
5/8 inch15.88View coilView straightSuction lines on mid-size split and ducted ACs and small cold rooms
3/4 inch19.05View coilView straightSuction lines on larger split, ducted and packaged AC units
7/8 inch22.23View coilView straightSuction lines on larger ducted and packaged units and cold room condensing units
1 1/8 inch28.58View coilView straightSuction and discharge lines on packaged units, cold rooms and small chiller plant
1 1/4 inch31.75View coilNot listedLarger lines where this size is already installed; check the match on site
1 3/8 inch34.93Not listedView straightSuction headers on cold rooms, multi-compressor racks and chiller plant
1 5/8 inch41.28View coilView straightLarge suction headers and risers on commercial refrigeration and chiller plant
2 1/8 inch53.98View coilView straightMain suction headers on large refrigeration racks, chillers and industrial cooling plant

Wall thickness and length per straight piece depend on the batch, so confirm both with your quote, especially for R410A and R32 systems.

When to choose a coil

  • Split AC installations where the line set runs along walls and through corners.
  • Repairs where only a short length is needed.
  • Small sizes such as 1/8 and 1/4 inch, which are only listed as coils.
  • Jobs where fewer joints means fewer leak points.

When to choose straight pipe

  • Plant rooms, compressor racks and chiller headers.
  • Exposed runs that must look neat and stay straight.
  • Larger sizes, including 1 3/8 inch, which is listed as straight only.
  • Brazed systems built with copper elbows, tees and reducers.

Frequently asked questions

What is the difference between a copper pipe coil and a straight copper pipe?

A coil is soft annealed copper wound into a 15 m roll that bends by hand or with a bender. A straight pipe is hard-drawn copper supplied in rigid lengths that stay straight and are joined with brazed fittings.

Are copper pipe sizes measured on the inside or the outside?

Refrigeration copper tube is named by its outside diameter (OD). A 1/2 inch tube has an outside diameter of 12.7 mm.

Which copper pipe sizes does a split AC need?

Small wall split units commonly use 1/4 inch for the liquid line and 3/8 or 1/2 inch for the suction line. Always follow the sizes printed in the indoor or outdoor unit manual.

Is a copper pipe roll the same as a copper pipe coil?

Yes. Roll and coil are two names for the same soft copper tube wound into a coil.

Can I use these copper pipes for R410A and R32?

Confirm the wall thickness with your quote before you order. R410A and R32 run at higher pressures than R22, so the tube wall must suit the system pressure.

Do I need to insulate copper refrigerant pipes?

Yes, the suction line in particular. Insulation stops condensation and heat gain. Match the Armaflex tube size to the copper OD; see our insulation range.

What tools do I need to install copper pipe?

A tube cutter, deburrer, flaring tool, tube bender for coils, and brazing equipment for straight lengths. Browse our refrigeration and AC tools.

How do I order copper pipe from Sparks Plumbing Experts?

Send the sizes, coil or straight form and quantity on WhatsApp 0726 086 895 or email sparksplumbingexperts@gmail.com. We supply from Enterprise Road, Industrial Area, Nairobi.

Need copper pipe for a job? Send the sizes, coil or straight, and the quantity on WhatsApp 0726 086 895 and we will confirm what is available.

Request a Quote

List the items, sizes and quantities you need. We reply with prices and availability.